You are here : Products > PVc Insulated Cables > Flexible Multi Core Cables
 
Flexible Multi Core Cables

These Flexible Multi - core cables are used for Electric Power Supply, modern electric appliances & equipments etc. Standards as IS : 694 & Customers Requirements.

"Poly Flex" brand PVC insulated & sheathed flexible multi- core wires, with bright annealed copper conductor, voltage up to & including 650/1100 volts grade with IS-694/90 mark.


"Poly Flex" Plain Copper Conductor, PVC insulated and sheathed 650/1100 V, MultiCore flexible as per IS : 694/1990 with ISI mark
Area in"Sq. mm"
Conductor
construction
No. Wire/ "mm"
Conductor
Dia.in "mm"
Max. DC
Resistance
"W/Km"at 200C
Insulation
Thickness in "mm"Nominal
CoreDia
(Approx.)
Current
Rating in "Amp".
Sheath thickness
in "mm" nominal.
Overall Diameter
in "mm" approx.
2 Core
3 Core
4 Core
2 Core
3 Core
4 Core
0.50
16/0.20
0.94
39.0
0.60
2.20
0.90
0.90
0.90-
6.20
6.60
7.20
4
0.75
24/0.20
1.15
26.0
0.60
2.50
0.90
0.90
0.90
6.80
7.20
7.90-
7
1.00
32/0.20
1.34
19.5
0.60
2.60
0.90
0.90
0.90
7.00
7.50
8.10
12
1.50
*30/0.20
1.64
13.3
0.60
2.90
0.90
0.90
1.00
7.60
8.10
9.00
15
2.50
**50/0.25
2.08
7.98
0.70
3.50
1.00
1.00
1.00
9.00
9.60
10.50
20
4.00
56/0.30
2.61
4.95
0.80
4.30
1.00
1.00
1.00
10.6
11.3
12.4
27

Flexible Multi -Core Cables
"Poly Flex" Plain Copper Conductor, PVC insulated and sheathed 650/1100 V, MultiCore Flexible Cable
Area in"Sq. mm"
Conductor
construction No.
Wire/ "mm"
Conductor
Dia. in "mm"
Max. DC
Resistance
"W/Km"at 200C
Insulation
Thickness in "mm"Nominal
Core Dia
(Approx.)
Sheath thickness in "mm" nominal.
Overall Diameter in "mm" approx.
Current
Rating in "Amp".
2 Core
3 Core
4 Core
2 Core
3 Core
4 Core
6.00
84/0.30
3.50
3.30
0.80
5.10
1.15
1.15
1.40
12.6
13.4
15.2
33
10.0
140/0.30
4.60
1.91
1.00
6.60
1.40
1.40
1.40
16.0
17.0
18.8
45
16.0
101/0.45
6.00
1.21
1.00
8.00
1.40
1.40
1.40
18.8
20.1-
22.2
60
25.0
158/0.45
7.60
0.078
1.20
10.0
2.00
2.00
2.00
24.0
25.6
28.2
75
35.0
220/0.45
8.70
0.554
1.20
11.1
2.00
2.00
2.00
26.3
28.0
31.0
95

"Poly Flex" Multi -core round flexible cable (6 cores to 30 cores) generally as per IS : 694/1990
Area "sq.mm".
0.50
0.75
1.00
1.50
2.50
4.00
General Construction no. of wire/ "mm"
16/0.20
24/0.20
32/0.20
*30/0.20
**50/0.25
56/0.30
Conductor Dia in "mm"
0.94
1.20
1.34
1.64
2.08
2.61
Avg. Insu. Thickness in "mm"
0.60
0.60
0.60
0.60
0.70
0.80
Core Dia in "mm"
2.20
2.50
2.60
2.90
3.50
4.30
No. of Cores
6 Avg. Sheath thickness "mm"
0.90
1.00
1.00
1.00
1.10
1.20
App. Overall Dia "mm"
8.50
9.50
9.80
10.7
12.7
15.3
7 Avg. Sheath thickness "mm"
0.90
1.00
1.00
1.00
1.10
1.20
App. Overall Dia "mm"
8.50
9.50
9.80
10.7
12.7
15.3
8 Avg. Sheath thickness "mm"
1.00
1.00
1.00
1.10
1.20
1.30
App. Overall Dia "mm"
9.30
10.4
10.7
11.9
14.1
16.9
10 Avg. Sheath thickness "mm"
1.00
1.10
1.10
1.10
1.30
1.40
App. Overall Dia "mm"
10.8
12.2
12.6
13.8
16.6
20.0
12 Avg. Sheath thickness "mm"
1.00
1.10
1.10
1.10
1.30
1.40
App. Overall Dia "mm"
11.2
12.6
13.0
14.3
17.2
20.7
14 Avg. Sheath thickness "mm"
1.10
1.10
1.10
1.20
1.30
1.40
App. Overall Dia "mm"
12.0
13.3
13.7
15.2
18.1
21.8
16 Avg. Sheath thickness "mm"
1.10
1.20
1.20
1.20
1.40
1.50
App. Overall Dia "mm"
12.6
14.2
14.6
16.0
19.3
23.2
19 Avg. Sheath thickness "mm"
1.10
1.20
1.30
1.30
1.40
1.50
App. Overall Dia "mm"
13.8
14.9
15.6
17.1
20.8
24.6
24 Avg. Sheath thickness "mm"
1.20
1.30
1.30
1.40
1.40
1.50
App. Overall Dia "mm"
15.6
17.6
18.2
20.2
23.8
28.8
30 Avg. Sheath thickness "mm"
1.30
1.30
1.30
1.40
1.40
1.50
App. Overall Dia "mm"
16.8
18.7
19.3
21.5
25.7
30.6
  Max. Conductor Resistance in "W/km" at 200C.
39.0
26.0
19.5
13.3
7.98
4.95
Recommended Current Rating in "AMP"
4
7
12
15
20
27