Control Cables

These cables are used for low volatge Electrical power station, indoor or Outdoor,
all kinds of Industrial Applications.

Standards as per IS - 1554 (Part-1)

Max. Conductor D.C. Resisitance at 200C conductor size 1.50 sq.mm - 12.1 W/km (Bare) and 12.2 W /km (Tinned copper) 2.50 sqmm - 7.41 W/km (Bare) and 7.56 W/km (Tinned Copper)


No.of Core & C.S. Area
Thick of PVC Insul
Thick of Inner Sheath
Thick of Outer Sheath
Appx. O.D.
Appx. Net Wt of Cable
Current Rating
No. x "sq. mm"
Nom. "mm"
"mm"
Direct in Ground "Amps"
In Air/ Duct Amps"
Min. "mm"
"mm" (Nom)
"kg/km"
2 x 1.50
0.80
0.30
1.80
11.8
185
23
20
3 x 1.50
0.80
0.30
1.80
12.3
190
21
17
4 x 1.50
0.80
0.30
1.80
13.2
225
21
17
5 x 1.50
0.80
0.30
1.80
14.1
260
16
14
6 x 1.50
0.80
0.30
1.80
15.1
295
15
13
7 x 1.50
0.80
0.30
1.80
15.1
315
14
13
10 x 1.50
0.80
0.30
1.80
18.4
425
13
11
12 x 1.50
0.80
0.30
1.80
18.9
480
12
10
14 x 1.50
0.80
0.30
1.80
19.8
535
11
10
16 x 1.50
0.80
0.30
1.80
20.7
595
11
9
19 x 1.50
0.80
0.30
2.00
22.5
720
10
9
24 x 1.50
0.80
0.30
2.00
25.8
880
9
8
27 x 1.50
0.80
0.30
2.00
26.3
960
9
8
30 x 1.50
0.80
0.30
2.00
27.2
1080
9
7
37 x 1.50
0.80
0.30
2.00
29.1
1230
8
7
2 x 2.50
0.90
0.30
1.80
13.0
230
32
27
3 x 2.50
0.90
0.30
1.80
13.6
240
27
24
4 x 2.50
0.90
0.30
1.80
14.6
290
27
24
5 x 2.50
0.90
0.30
1.80
15.7
335
23
19
6 x 2.50
0.90
0.30
1.80
16.9
385
21
18
7 x 2.50
0.90
0.30
1.80
16.9
420
20
17
10 x 2.50
0.90
0.30
1.80
20.8
570
18
15
12 x 2.50
0.90
0.30
2.00
22.2
690
17
14
14 x 2.50
0.90
0.30
2.00
23.2
775
16
13
16 x 2.50
0.90
0.30
2.00
24.3
860
15
13
19 x 2.50
0.90
0.30
2.00
25.5
985
14
12
24 x 2.50
0.90
0.30
2.00
29.4
1215
13
11
27 x 2.50
0.90
0.30
2.00
30.0
1330
12
10
30 x 2.50
0.90
0.30
2.00
31.0
1450
12
10
37 x 2.50
0.90
0.40
2.20
34.1
1790
11
9

Control Cables
No.of Cores & Cross Sectional Area
Thickness of PVC Insulation
Thickness of Inner Sheath
Strip Armoured Cable
Wire Armoured Cable
Current Rating
No. x "sq. mm"
Nom. "mm"
Min. "mm"
Strip Size
Thick of PVC Outer Sheath "mm" min
Appx. O.D. "mm"
Appx. Net Wt of Cable "kg/km"
Wire  Dia "mm"
Thick of PVC Outer Sheath "mm" min
Appx. O.D. "mm"
Appx. Net Wt of Cable "kg/km"
Direct in Ground "Amps"
In Air/ Duct "Amps"
2 x 1.50
0.80
0.30
-
-
-
-
1.40
1.24
13.6
415
23
20
3 x 1.50
0.80
0.30
-
-
-
-
1.40
1.24
14.1
430
21
17
4 x 1.50
0.80
0.30
-
-
-
-
1.40
1.24
15.0
490
21
17
5 x 1.50
0.80
0.30
-
-
-
-
1.40
1.24
15.9
545
16
14
6 x 1.50
0.80
0.30
-
-
-
-
1.40
1.24
16.9
605
15
13
7 x 1.50
0.80
0.30
-
-
-
-
1.40
1.24
16.9
630
14
13
10 x 1.50
0.80
0.30
-
-
-
-
1.40
1.40
20.6
835
13
11
12 x 1.50
0.80
0.30
4 x 0.80
1.24
19.5
760
1.60
1.40
21.5
950
12
10
14 x 1.50
0.80
0.30
4 x 0.80
1.40
20.8
830
1.60
1.40
22.4
1040
11
10
16 x 1.50
0.80
0.30
4 x 0.80
1.40
21.7
920
1.60
1.40
23.3
1130
11
9
19 x 1.50
0.80
0.30
4 x 0.80
1.40
23.1
1040
1.60
1.40
24.7
1265
10
9
24 x 1.50
0.80
0.30
4 x 0.80
1.40
26.4
1250
1.60
1.40
28.0
1510
9
8
27 x 1.50
0.80
0.30
4 x 0.80
1.40
26.9
1355
1.60
1.40
28.5
1610
9
8
30 x 1.50
0.80
0.30
4 x 0.80
1.40
27.8
1430
1.60
1.40
29.4
1700
9
7
37 x 1.50
0.80
0.30
4 x 0.80
1.40
29.7
1670
1.60
1.40
31.3
1960
8
7
2 x 2.50
0.90
0.30
-
-
-
-
1.40
1.24
14.8
500
32
27
3 x 2.50
0.90
0.30
-
-
-
-
1.40
1.24
15.4
520
27
24
4 x 2.50
0.90
0.30
-
-
-
-
1.40
1.24
16.4
590
27
24
5 x 2.50
0.90
0.30
-
-
-
-
1.40
1.24
17.5
660
23
19
6 x 2.50
0.90
0.30
-
-
-
-
1.40
1.24
18.7
745
21
18
7 x 2.50
0.90
0.30
-
-
-
-
1.40
1.24
18.7
780
20
17
10 x 2.50
0.90
0.30
4 x 0.80
1.40
21.8
900
1.60
1.40
23.4
1110
18
15
12 x 2.50
0.90
0.30
4 x 0.80
1.40
22.8
1020
1.60
1.40
24.4
1240
17
14
14 x 2.50
0.90
0.30
4 x 0.80
1.40
23.8
1130
1.60
1.40
25.4
1340
16
13
16 x 2.50
0.90
0.30
4 x 0.80
1.40
24.9
1210
1.60
1.40
26.5
1455
15
13
19 x 2.50
0.90
0.30
4 x 0.80
1.40
26.1
1355
1.60
1.40
27.7
1605
14
12
24 x 2.50
0.90
0.30
4 x 0.80
1.40
30.0
1655
1.60
1.56
32.0
1970
13
11
27 x 2.50
0.90
0.30
4 x 0.80
1.40
30.6
1770
1.60
1.56
32.6
2100
12
10
30 x 2.50
0.90
0.30
4 x 0.80
1.56
32.0
1940
1.60
1.56
33.6
2250
12
10
37 x 2.50
0.90
0.40
4 x 0.80
1.56
34.7
2300
2.00
1.56
37.1
2900
11
9